Solar builds complete gas compressor packages that are ready to go to work in all gas compression and transmission applications, no matter where the job is. Solar designs and manufactures every turbomachinery package using quality and safety systems recognized worldwide as standards of excellence.
Models
Titan 350 – 39 MW
Power
52,500 HP
Heat Rate
6200 BTU/HP-HR
Exhaust Flow
855,000 LB/HR
Exhaust Temperature
910ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Titan 350 – 35 MW
Power
47,000 HP
Heat Rate
6250 BTU/HP-HR
Exhaust Flow
820,080 LB/HR
Exhaust Temperature
860ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Titan 250
Power
31,900 HP
Heat Rate
6360 BTU/HP-HR
Exhaust Flow
541,590 LB/HR
Exhaust Temperature
865ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Titan 130
Power
23,470 HP
Heat Rate
6800 BTU/HP-HR
Exhaust Flow
452,830 LB/HR
Exhaust Temperature
895º F
Combustion System
SOLONOX (DLE) CONVENTIONAL
Mars 100
Power
15,900 HP
Heat Rate
7395 BTU/HP-HR
Exhaust Flow
337,850 LB/HR
Exhaust Temperature
905ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Mars 90
Power
13,220 HP
Heat Rate
7655 BTU/HP-HR
Exhaust Flow
318,755 LB/HR
Exhaust Temperature
870ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Taurus 70
Power
11,110 HP
Heat Rate
7190 BTU/HP-HR
Exhaust Flow
215,990 LB/HR
Exhaust Temperature
935ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Taurus 60
Power
7700 HP
Heat Rate
7965 BTU/HP-HR
Exhaust Flow
171,690 LB/HR
Exhaust Temperature
950ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Centaur 50
Power
6130 HP
Heat Rate
8500 BTU/HP-HR
Exhaust Flow
149,380 LB/HR
Exhaust Temperature
960ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Centaur 40
Power
4700 HP
Heat Rate
9125 BTU/HP-HR
Exhaust Flow
150,320 LB/HR
Exhaust Temperature
835ºF
Combustion System
SOLONOX (DLE) CONVENTIONAL
Saturn 20
Power
1590 HP
Heat Rate
10,370 BTU/HP-HR
Exhaust Flow
51,615 LB/HR
Exhaust Temperature
970ºF
Combustion System
CONVENTIONAL